Motor Fault Description
Motor Fault
Value (MF
Command)
Error
Code
Error
Register
Speed limit exceeded: VX < LL[2] or VX > HL[2]
0x20000
0x8481
0x81
Stack overflow: fatal exception. May occur if CPU
cannot handle a real-time load due to too low a
sampling time.
0x40000 0x6180
0x81
CPU exception: fatal exception.
0x8000
0x6181
0x81
Timing Error
0x100000
0x5281
0x81
Motor stuck: motor powered but not moving
according to definition of CL[2] and CL[3].
0x200000 0x7121
0x21
Position limit exceeded: PX < LL[3] or PX > HL[3]
(UM=5), or PY < LL[3] or PY > HL[3] (UM=4).
0x400000 0x8680
0x81
Reserved 0x8000000
0x1000
0x81
Cannot tune current offsets
0x10000000
0x8381
0x81
Cannot start motor
0x20000000
0xFF10
0x81
Reserved 0x800000
0x8680
0x81
Reserved 0x1000000
0x8312
0x3
Cannot start motor
0x20000000
0x5400
0x21
Under-voltage: power supply is shut down or it
has too high an output impedance.
0x3000 0x3120
0x5
Over-voltage: power-supply voltage is too high
or servo drive could not absorb kinetic energy
while braking a load. A shunt resistor may be
required.
0x5000 0x3310
0x5
Reserved 0x7000
0x3100
0x5
Reserved 0x9000
0x2311
0x3
Short circuit: motor or its wiring may be
defective, or drive is faulty.
0xb000 0x2340
0x3
Temperature: drive overheating. The
environment is too hot or heat removal is not
efficient. Could be due to large thermal resistance
between drive and its mounting.
0xd000 0x4310
0x9
Reserved 0xf000
0x5282
0x81
Table 13-3: Motor Shut Down by Fault Emergency Error Codes
CANopen DS 301 Implementation Guide