Object 0x2f41: ds402 configuration object, Object 0x2f41: ds402 configuration object -33 – ElmoMC CANopen DS 301 Implementation Guide User Manual
Page 110

Object 0x2F41: DS402 Configuration object
This bit field object gives several configuration options to the DS402 protocol. It resets to
0 after boot reset and must be set again in such cases.
Object description:
Index 2F41h
Name
DS402 Configuration object
Object code
VAR
Data type
UNSIGNED32
Category
Entry description:
Access Read/Write
PDO mapping
No
Value range
No
Default value
0
Data description:
31
2 1 0
Reserved Start
Motion
in PP
mode
Fast PV mode
Fast PV mode – Bit 0:
Allows fast treatment of the DS402 profile velocity mode. In this case the following
objects are not considered: profile acceleration (0x6083) profile deceleration (0x6084),
polarity (0x607E), acceleration factor (0x6097), velocity limit (0x607F), velocity
encoder factor (0x6094). Any settings of the AC & DC can be done with the Elmo
Binary Interpreter. The target velocity (0x60FF) is considered as counts/sec.
Start Motion in PP Mode – Bit 1 :
This bit determines the behavior of the profile position (PP) when motion begins.
‘0’ - the motion begins when bit 4 in the control word (New set point) is reset from
‘1’ to ‘0’. ‘0’ is the default value of bit 1 of this Object ( 0x2F41). It maintains
compatibility with previous firmware versions.
“1” - the motion begins when bit 4 in the control word (New set point) is set from ‘0’
to ‘1’.
CANopen DS 301 Implementation Guide
Manufacturer-specific Objects
MAN-CAN301IG (Ver. 2.1)
13-33