Chapter 10: The OS Interpreter
The OS interpreter is used to process any SimplIQ interpreter string command, and to
return the string results. The only limitation in its use is that the returned strings cannot
exceed 500 characters in length, a limit that must be considered when uploading recorded
data. A more efficient — and unlimited — method to upload recorder data is to use
object 0x2030.
To issue an OS interpreter command
1. Set OS mode to evaluate the string immediately, by writing 0 to object 0x1024.
2. Write the command string to object 0x1023, sub-index 1.
The command execution can be resolved by an event-driven PDO (object 0x2F20) or by
polling object 0x1023, sub-index 2. The polling may return:
0xFF: Command still executing (can be aborted by writing 3 to object 0x1024).
0x1: Command successfully executed. Result is waiting for read.
0x3: Command rejected. Error code waiting for read.
When the response is ready, it can be read from object 0x1023, sub-index 3.
Example:
The following describes the use of the OS interpreter to send the command PX=1234.
Client initiates OS Evaluate Immediately mode:
RSDO
Object
0x1024
23 24 10 00 00 00 00 00
Server replies:
TSDO
Object
0x1024
60 24 10 00 00 00 00 00
Client initiates segmented SDO download:
RSDO Object
0x1023
Sub-index
21 23 10 01 00 00 00 00
Server replies:
TSDO Object
0x1023
Sub-index
60 23 10 01 00 00 00 00
Client sends PX=1234 in one SDO:
RSDO
P X = 1 2
3 4
01 50 58 3D
31 32 33 34