JLG 510AJ Service Manual User Manual
Page 338
SECTION 6 - JLG CONTROL SYSTEM
6-56
– JLG Lift –
3121181
CHECKING INPUTS
Indicates that the inputs test is beginning. Every input is checked to
ensure that it is in its “normal” position; function switches should be
open, cutout switches should be closed, joysticks should be in neutral.
In platform mode any non-neutral platform switch or joystick is
reported; any active cutouts are reported.
In ground mode any non-neutral ground switches is reported; any
active cutouts are reported.
NOTE: Switches, which are not in use (due to the settings of machine dig-
its), are not checked.
NOTE: The pump pot is checked only for a wire-off condition; it can be at
any demand from creep to maximum.
Problems that can be reported include below messages.
CHECK XXXXXXX
The named switch is not in its “normal” position. Check switch & wiring.
CHECK XXXXXXX JOY
The named joystick appears to be faulty. Check joystick.
TESTING LAMPS
Indicates that the lamps test is beginning. Each lamp is energized in turn;
a prompt asks for confirmation that the lamp is lit.
ENTER must be pressed or clicked to continue the test.
NOTE: Lamps, which are not in use (due to the settings of machine dig-
its), are not checked.
NOTE: Platform Lamps are only tested in platform mode.
NOTE: The GM overload lamp and 500# capacity lamp are not tested.
NOTE: Head and tail lamps are tested in both platform and ground mode
if enabled by a machine digit.
TESTING ALARMS
Indicates that the alarms test is beginning. Each alarm is energized in
turn; a prompt asks for confirmation that the alarm is sounding.
ENTER must be pressed or clicked to continue the test.
NOTE: The platform alarm and the horn are only tested in platform
mode.
NOTE: The ground alarm is not tested if GROUND ALARM = NO.
Table 6-7. System Test Messages
Message Displayed on
Analyzer
Message Displayed on
Analyzer
Description