SECTION 6 - JLG CONTROL SYSTEM
3121181
– JLG Lift –
6-41
GEN SET CUTOUT:
13*
* Only visible if Gen Set /
Welder Menu selection
is not 0.
0
1
MOTION ENABLED: Motion enabled when generator is ON.
MOTION CUTOUT: Motion cutout in platform mode only.
0
H & T LIGHTS:
14
0
1
NO: No head and tail lights installed.
YES: Head and tail lights installed.
0
CABLE SWITCH:
15*
* Only visible under cer-
tain model selections.
* Certain market and
model selections will
alter the default setting.
0
1
NO: No broken cable switch installed.
YES: Broken cable switch installed.
0
LOAD SYSTEM:
16*
* Only visible under cer-
tain market selections.
* Certain market selec-
tions will limit load sys-
tem options or alter
default setting.
0
1
2
3
4
NO: No load sensor installed.
WARN ONLY: Functions in creep, overload lamp lit, platform alarm beeps (5
sec ON, 2 sec OFF).
CUTOUT PLATFORM: All functions cutout, overload lamp lit, platform alarm
beeps (5 sec ON, 2 sec OFF).
CUTOUT ALL: All functions cutout, flash overload light (500mS on, 500mS
off ), platform alarm beeps (5 sec ON, 2 sec OFF).
SPECIAL 1: Functions in creep, overload lamp lit, disables main telescope out
& main lift up, platform alarm beeps (5 sec ON, 2 sec OFF).
0
LOAD SENSOR:
17*
* Only visible if Load
Sensor Menu selection
is not 0 and under cer-
tain market selections.
* Certain market selec-
tions will limit load sen-
sor options.
0
1
1 ON ROTATOR: Use the on-board load sensor for all models except those
which use the Leveling Platform Module.
4 UNDER PLATFORM: Use the EIM for load sensing.
1
Table 6-5. Machine Configuration Programming Information Software Version P5.3 to P6.1
Configuration Label/
Digit
Number
Description
Default
Number