SECTION 6 - JLG CONTROL SYSTEM
3121181
– JLG Lift –
6-45
STARTER LOCKOUT:
6
0
1
DISABLED: Automatic pre-glow time determined by ambient air temperature;
engine start can be attempted at any time during pre-glow.
ENABLED: Automatic pre-glow time determined by ambient air temperature;
engine start is NOT permitted until pre-glow is finished.
0
Fuel Cutout
7
0
1
2
RESTART: Engine allowed to be restarted multiple times when very low
fuel level is reached.
ONE RESTART: Engine allowed to be restarted once for 2 minutes when very
low fuel level is reached.
ENGINE STOP: Engine not able to restart when very low fuel level is reached.
0
*This menu item is only visible if non-dual fuel engines are selected.
ENGINE SHUTDOWN:
8*
0
1
DISABLED: No engine shutdown.
ENABLED: Shutdown engine when coolant temperature is greater than 110 deg.
C or the oil pressure is less than 8 PSI.
1
TILT:
9*
1
2
3
4
5
6
5 DEGREES: Reduces maximum speed of all boom functions to creep when tilted
more than 5 degrees and above elevation; also reduces drive speed to creep.
4 DEGREES: Reduces maximum speed of all boom functions to creep when tilted
more than 4 degrees and above elevation; also reduces drive speed to creep.
3 DEGREES: Reduces maximum speed of all boom functions to creep when tilted
more than 3 degrees and above elevation; also reduces drive speed to creep.
4 DEGREES + CUT: Reduces maximum speed of all boom functions to creep
when tilted more than 4 degrees and above elevation; also disallows tower lift
up, tower telescope out, drive, main telescope out and main lift up.
3 DEGREES + CUT: Reduces maximum speed of all boom functions to creep
when tilted more than 3 degrees and above elevation; also disallows tower lift
up, tower telescope out, drive, main telescope out and main lift up.
5 DEGREES + CUT: Reduces the maximum speed of all boom functions to
creep when tilted more than 5 degrees and above elevation; also disallows
tower lift up, tower telescope out, drive, main telescope out and main lift up.
1
* Certain market selections will limit tilt options and alter default setting.
Note: Any of the selections above will light the tilt lamp when a tilted condition occurs and will sound the platform alarm when the machine is
also above elevation.
Table 6-6. Machine Configuration Programming Information Software Version P6.1 to Present
Configuration Label/
Digit
Number
Description
Default