Machine set-up parameters -22 – JLG 510AJ Service Manual User Manual
Page 304

SECTION 6 - JLG CONTROL SYSTEM
6-22
– JLG Lift –
3121181
Table 6-1. Machine Set-Up Parameters
Configurati
on
Digit
Parameter
Displayed on
Analyzer
Line 1
Description
Parameter
Value
Definition
Defaul
t
Numb
er
1
MODEL
NUMBER:
Displays/adjusts
machine model
1=400
400
1
2=450, 510
2=450, 510
3=600
3=600
4=601
4=601
5=800A
5=800A
6=800S
6=800S
7=1350S
7=1350S
8=1200S
8=1200S
1A
ENVELOPE
HEIGHT:
Displays/adjusts
envelope height.
Only displayed if
MODEL NUMBER
= 7 or 8.
1=1350S/135’MAX
1350S 135’ Envelope (Model 1350 only)
1 or 5,
per
MODE
L
NUM-
BER
selec-
tion
2=1350S/125’MAX
1350S 125’ Envelope (Model 1350 only)
3=1350S/120’MAX
1350S 120’ Envelope (Model 1350 only)
4=1350S/110’MAX
1350S 110’ Envelope (Model 1350 only
5=1200S/120’MAX
1200S 120’ Envelope (Model 1200 only)
6=1200S/110’MAX
1200S 110’ Envelope (Model 1200 only)
2
ENGINE:
Displays/adjusts
engine manufac-
turer/type
1=FORD EFI GAS
Ford LRG425EFI Gas
2
2=FORD EFI D/F
Ford LRG425EFI Gas with dual fuel
3=DEUTZ F4
Deutz F4M1011F, F4M2011, or BF4M2011 Diesel
4=DEUTZ F3
Deutz F3M1011F or F3M2011 Diesel
3
GLOW PLUG:
Display/adjusts
glow plug pres-
ence and on-
time. Only dis-
played if ENGINE
= 3 or 4
0=NO GLOW PLUGS
0 No glow plugs installed
0
2=”XX=XX SEC-
ONDS”
1-60Setting this number tells the controller how
many seconds after the EMS is pulled to output
to the glow plugs before permitting the engine
to be started
4
ENG SHUT-
DOWN:
Displays/adjusts
presence of the
engine shut-
down feature.
0=NO
No engine shutdown
1
1=SHUTDOWN
Shutdown engine when coolant temperature is
greater than 118° C (for the FORD engine) or the
oil pressure is less than 8 psi.