beautypg.com

JLG X17J Plus Operator Manual User Manual

Page 90

background image

The end of the automatic stabiliser raising cycle is shown on a screen for a few seconds. If
this screen is not shown, the automatic stabiliser raising procedure can still be considered
completed once all the four stabilisers have been completely retracted and consequently the
relevant cylinders are at the end of their stroke.

If problems occur during either of these procedures, immediately release the selected but‑
ton to stop all the movements. Stabilising the machine on a slope exceeding the allowed
limits may cause instability and consequently harm to or even death of operators or other
persons in and around the working area. Work must only be performed with the machine
stabilised at an inclination under the limits specified by the manufacturer.

The elevating platform is considered stabilised when the slope is less than 1° and the tracks
are raised at least 5 cm from the ground. NEVER WORK AT A HEIGHT WITH THE
TRACKS NOT COMPLETELY RAISED FROM THE GROUND.

6.4.11 TRACK GAUGE EXTENSION

To adjust the track gauge, proceed as follows:

Use buttons 3‑9 to extend/narrow the track gauge.

NOTE: the track gauge extension operations should be performed with the machine stabili‑
sed and lifted from the ground. If this is not possible, perform the extension operations with
the tracks moving.
Do not extend/narrow the track gauge when the tracks are stationary and resting on the
ground.

BOOM LIFT MODELS X17JPLUS

JLG

86

X17JPR0020413

IMPORTANTE

WARNING