7.7 PERIODICAL MAINTENANCE INTERVALS

HONDA PETROL ENGINE

* First operation.
** At least every 3 months.
*** At least every 5 years.

# Anyway every year. If the tightening is not correct replace the nuts with two new with the same
specifications and restore the connection without using oil or grease.

113

BOOM LIFT MODELS X17JPLUS

JLG

X17JPR0020413

PART

INTERVENTION

BEFORE

STARTING

AS NEEDED

INTERVAL (HOURS)

10

50

100

250

500

1000

2000

DRY AIR FILTER

CHECK, CLEAN

CHANGE

ENGINE OIL

CHECK LEVEL

CHANGE

*

OIL SUMP

CLEAN

FUEL TANK AND NET

CLEAN

HYDRAULIC OIL

CHECK LEVEL

CHANGE

HYDRAULIC OIL

FILTER

CHANGE CARTRIDGE

*

ARTICULATED JOINT

POINTS

GREASE

*

BATTERY

CHECK ELECTROLYTE

LEVEL

REDUCTION GEAR

OIL

CHECK LEVEL

CHANGE

*

MACHINE

GENERAL PERIODICAL

CHECKS

*

EXTENSION ARM

INTERNAL SLIDING

RING

CHECK WEAR

CHANGE

TURNTABLE BOLT

TIGHTENING

CHECK

*

NUT FIXING PINS

BASKET

CHECK TORQUE

200 Nm

#