JLG X17J Plus Operator Manual User Manual
Page 122
maintenance and inspection records.
The structural inspection must be carried out under the supervision of a professional engi‑
neer.
This inspection must:
1.
consider the service history of the aerial platform in terms of hours of service, severity of
use, and number and variability of users;
2. review the inspection and maintenance record of the aerial platform;
3. verify the efficiency of all operating controls;
4. perform a visual inspection of the aerial platform;
5. consider recommendations of the manufacturer regarding the aerial platform, including
manufacturer’s safety bulletins.
E – MAINTENANCE
Before adjustments and repairs are started on the aerial platform, the following precautions
must be taken:
1.
the power system must be stopped, and the starting devices must be rendered inoperati‑
ve;
2. all controls must be in the OFF position and all operating systems must be secured
against accidental activation by brakes, chocks or other means;
3. elevating and rotating assembly and platform must be completely lowered, if possible,
or otherwise secured by blocking or propping;
4. the hydraulic oil pressure must be released from all hydraulic circuits before loosening
or removing hydraulic components;
5. safety props or latches must be installed where applicable;
6. other precautions must be adopted as specified in the user and operation manual.
7.10 GENERAL PERIODICAL CHECKS
After the first 2000 hours of operation, have a general check run on the machine, at a certi‑
fied JLG service centre, where the general condition of the machine will be assessed and
they fill the form of periodic inspection general.
Subsequent checks should be performed every 1000 hours of operation.
To find the nearest certified JLG service centre, contact your reseller.
BOOM LIFT MODELS X17JPLUS
JLG
118
X17JPR0020413