N.B.: the CODE column indicates the CAN CODE in the message sent by the battery charger.
The normal mains voltage tolerance is the rated value ±15%.

BOOM LIFT MODELS X17JPLUS

JLG

158

X17JPR0020413

CODE

MEANING

74

Driver shorted
Cause: Relay power supply fault.
Solution: Check relay power supply. This is generally a temporary problem due
to certain working conditions. If problem persists, replace inverter.

75

Driver shorted
Cause: Relay power supply fault.
Solution: Check relay power supply. This is generally a temporary problem due
to certain working conditions. If problem persists, replace inverter.

76

Coil shorted
Cause: Problem detected with relay coil.
Solution: Make sure relay coil is intact.

78

VACC not OK
Cause:
Solution: This is generally a temporary problem due to certain working condi‑
tions. If problem persists, replace inverter.

79

Incorrect start
Cause: Incorrect starting procedure.
Solution: Check electrical connections. This is generally a temporary problem
due to certain working conditions. If problem persists, replace inverter.

86

Pedal wire KO
Cause:
Solution: This is generally a temporary problem due to certain working condi‑
tions. If problem persists, replace inverter.

93

Wrong set batt
Cause: With power connected, battery test detected incorrect batteries fitted.
Solution: Replace batteries with the original ones.

94

Current sensor KO
Cause: Set up procedure for maximum current in progress.
Solution: Contact after‑sales service.

99

Check up needed
Cause:
Solution: Contact after‑sales service.