9 available options, Hydraulic drive option, Figure 6-15: hydraulic drive option – Hale MBP Booster User Manual
Page 88: Installation notes
![background image](/manuals/545142/88/background.png)
87
Silencer Series Booster Pump, p/n: 029-0020-83-0
Preventive Maintenance
❑
6.9
AVAILABLE OPTIONS
Hydraulic Drive Option
(See Figure 6-15: “Hydraulic Drive Option.”)
Figure 6-15: Hydraulic Drive Option
17. If not already done, remove the hydraulic motor from the hydraulic adapter.
18. Remove the 7/16” hex screws and hardware securing the hydraulic adapter
flange to the gearbox housing.
19. Slide (pull back) the coupling from the drive shaft.
20. Remove the drive shaft key and set safely aside.
Installation Notes
(See Figure 6-15: “Hydraulic Drive Option.”)
To install, follow the preceding steps in the reverse order. Use Loctite #246
High Temperature Removable Threadlock (or equal) install the bushings
and elbows in the water manifold.
This manual is related to the following products: