beautypg.com

Relief valve does not relieve, Relief valve does not recover, Relief valve opens – Hale MBP Booster User Manual

Page 60: Unable to optain proper setting, Figure 5-2: troubleshooting charts - continued

background image

59

Silencer Series Booster Pump, p/n: 029-0020-83-0

Troubleshooting

RELLEF VALVE
DOES NOT
RELIEVE PRES-
SURE WHEN
VALVES ARE
CLOSED

Incorrect setting of
control (PDM) Valve

• Check and repeat proper procedures for setting relief valve

system.

• See Section 3 Operation, heading “Relief Valve Procedures” on

page 35.

Relief valve
inoperative

• Possibly in need of lubrication. Remove valve from pump, dis-

mantle, clean and lubricate.

• Refer to relief valve manual and follow maintenance instructions

for disassembly, cleaning and lubrication.

RELIEF VALVE
DOES NOT
RECOVER AND
RETURN TO
ORIGINAL
PRESSURE SET-
TING AFTER
OPENING
VALVES

Dirt in system caus-
ing sticky or slow
reaction

• Check and repeat proper procedures for setting the relief valve

system.

• See Section 3 Operation, heading “Relief Valve Procedures” on

page 35.

Relief valve
inoperative

• Blocked bleed orifice - clean the bleed orifice with a small wire or

straightened paper clip.

• Refer to relief valve manual and follow maintenance instructions

for disassembly, cleaning and lubrication.

RELIEF VALVE
OPENS WHEN
CONTROL
VALVE IS
LOCKED OUT

Drain hole in hous-
ing, piston or sens-
ing valve is blocked

• Clean the valve drain hole with a small wire or straightened paper

clip.

• Refer to relief / sensing valve manual and follow maintenance

instructions for disassembly, cleaning and lubrication.

UNABLE TO
OBTAINE
PROPER SET-
TING ON
RELIEF VALVE

Chart continued on

next page.

Using the wrong
procedures

• Check instructions for setting the relief valve and reset.

• See Section 3 Operation, heading “Relief Valve Procedures” on

page 35.

Blocked strainer

• Check and clean the strainer in the supply line from the pump dis-

charge to the control valve. Check truck manual for the exact
location.

• Check and clean tubing lines related to the relief and control

valves.

Dirty control valve

• Remove the control valve and clean.

“Hunting” condition

• Insufficient water supply from the pump to the control valve.

• Check the strainer and relief valve system for flow restrictions.

• Remove and clean the control valve.

Condition

Possible

Cause

Suggested Corrective Action

Figure 5-2: Troubleshooting Charts

This manual is related to the following products: