Preventive Maintenance

42

Silencer Series Booster Pump, p/n: 029-0020-83-0

During Freezing Weather

In freezing weather, drain the pump as follows:

1. Open all discharge and suction valves, remove suction tube caps and dis-

charge valve caps.

2. Open pump body drain cocks and/or Hale multiple drain valve.

3. After the pump is completely drained, replace all caps and close all valves.

Pumping from Salt Water, Contaminated Water, or with Foam Solution

Thoroughly flush the pump and suction hoses using fresh water from a
hydrant or other clean water source.

After pumping foam, flush as above until all residue of foam is flushed from
the system.

4.4

WEEKLY

Test the relief valve system

Test the priming system

Test the pump shift warning indicator lights

Perform valve maintenance

Check and clean the intake strainers

Check any auxiliary engines

Verify all gauges are in working order

Operate pump controls

Inspect water and foam tanks

Check roof and bumper turrets

Follow local maintenance and test procedures

Relief Valve Test

When the relief valve is not in operation, keep the hand wheel set above the
normal operating pressure. (See Figure 4-1: “TPM Relief Valve Control,” on
page 43.)