beautypg.com

5 mechanical seal assembly, Figure 6-8: mechanical seal overview / replacement, Removing the seal – Hale MBP Booster User Manual

Page 75

background image

Preventive Maintenance

74

Silencer Series Booster Pump, p/n: 029-0020-83-0

6.5

MECHANICAL SEAL ASSEMBLY

(See Figure 6-8: “Mechanical Seal Overview / Replacement.”) Also see Fig-
ure 6-4: “Booster Pump Parts Breakdown” on page 69.

Figure 6-8: Mechanical Seal Overview / Replacement

IMPORTANT !

IF WATER LEAKAGE FROM THE DRAIN HOLE IN THE PUMP HEAD IS
NOTICED, THE IMPELLER MUST BE REMOVED AND THE MECHANICAL SEAL
MUST BE INSPECTED.

Removing the Seal

1. To expose the mechanical seal, remove the volute and the impeller as

described in the following sections.

“Servicing the Booster Pump,” on page 69

“Volute (Pump Body),” on page 69

“Impeller,” on page 71

This manual is related to the following products: