Hardware-level test parameters – Brocade Communications Systems 415 User Manual
Page 70
![background image](/manuals/52046/70/background.png)
56
Brocade Adapters Administrator’s Guide
53-1001583-01
Diagnostics using HCM
5
3. Click the check box that corresponds to the port test you are running.
4. Specify the parameters based on parameter information found in
.
NOTE
Click the Stop on Error check box if you want the test to stop running if an error occurs.
5. Click Start to run the test.
Hardware-level test parameters
TABLE 12
Hardware-level test parameters
Hardware-level test
Parameter
Test Options
Memory test
NOTE: During the test, IOC will
be disabled.
None
You can enable or disable this test.
Regardless of test cycle set value, the
Memory Test will run only once.
PCI loopback test
Frame Count
Integer from 0 - 4,294,967,295. The
default value is 8192.
Data Pattern
Default value is A5A5A5A5.
Test Cycle
The number of times the test runs. The
default value is 10.
Port loopback test
NOTE: For an External
Loopback test, you must plug
in the loopback connector.
For a Brocade 804 mezzanine
card, a pass-through module is
required for an External
Loopback test.
Subtest ID
•
Internal
•
External
•
Serdes
Link Speed
2, 4, and 8 Gbps
Frame Count
Integer from 0 - 4,294,967,295. The
default value is 8192.
Test Cycle
The number of times the test runs. The
default value is 10.
Data Pattern (hexadecimal)
Default value is A5A5A5A5.
Queue test
Sends a health check message
from host to firmware through
message queues memory
mapped over the PCI.
You can enable or disable this
test.
Queue number from 0-3. Because HCM
only allows you to enable or disable the
queue test (and not specify an integer),
all the queues will be tested.