Brocade Communications Systems 415 User Manual
Page 160

146
Brocade Adapters Administrator’s Guide
53-1001583-01
ioc
B
-Delay
Sets the delay timeout interrupt value. A delay can be between 0 to 1125
microseconds. A delay value of 0 disables the delay timeout interrupt. The
default delay value is 25 for an HBA.
Example
#bcu ioc
--
query 1/0
chip rev: Rev-B
manufacturer: Brocade
serial#: ARZ0351D00B
model_descr: BR-1020
pwwn: 10:00:00:05:1e:55:1d:3c
nwwn: 20:00:00:05:1e:55:1d:3c
f/w ver: pvt_bld03 05/05/2009 15.12.12
bios ver:
port count: 2
status is: operational
ssid: 0x0014
vendor id: 0x1657
device id: 0x0014
pci function: 0
IOC type:
interrupt coalescing: on
interrupt delay: 25 us
interrupt latency: 0 us
# bcu ioc
--
stats 1/0
Num suspends: 7
bcu ioc
--
statsclr 1/0
ioc stats cleared.
bcu ioc
--
enable 1/0
ioc is enabled
bcu ioc
--
enable ad1_p0
ioc is already enabled
bcu ioc
--
disable 1/0
ioc is disabled
bcu ioc
--
disable ad1_p0
ioc is already disabled
bcu
--
intr 1/0
--
coalesce off
interrupt coalescing has been turned off
bcu ioc
--
intr 1/0
--
coalesce on
The intr settings have been configured with value(s):
Coalesce: on
bcu ioc
--
intr 1/0
--
coalesce on 12 19
The intr settings have been configured with value(s):
Coalesce: on
Delay: 19 (micro-seconds)
Latency: 12 (micro-seconds)
See Also