beautypg.com

Brother BES-962BC User Manual

Page 251

background image

Chapter 11 Error code list

BES-962BC • BES-1262BC

249

Code

E-C3

E-C4

E-C5

E-C6

E-C7

E-C8

E-C9

E-CA

E-CB

E-CC

E-CD

E-CE

E-CF

E-D0

E-D1

E-D2

E-D3

E-E1

E-E2

E-E3

E-E4

E-E5

E-E6

E-E7

E-E8

Error

Embroidering data buffer empty

Presser foot down error

Measured voltage value could not be received form
the lower shaft motor CPU.

Voltage value could not be transferred to the lower
shaft motor CPU.

Lower shaft error

Hook motor origin point error

Embroidering start error

No sewing permission is given from PC.

Spindle rotation speed error

Shuttle thread entanglement automatic reset

Speed command can not be received.

Cylinder bed position error

Rated voltage value could not be received from the
lower shaft motor CPU.

Power PC board error

Cooling fan motor stop B Tum the power off.

Power voltage upper limit error

Power voltage lower limit error

X-axis pulse motor overcurrent stop

Y-axis pulse motor overcurrent stop

Cooling fan motor stop A Press R.

Lower shaft communication error

Over-run error during interfacing to main PCB CPU

Framing error during interfacing to main PCB CPU

Parity error during interfacing to main PCB CPU

Receiving time up error during interfacing to main
PCB CPU

Measures

Is the IF cable disconnected? If it is connected normally, the cable or the
main board is faulty.

Press the

STOP

or turn on the F/B switch on the head to either side. If the

same error occurs again, adjust the presser foot switch.

This is not usually displayed.

The machine may be being tested in the BC test mode. Exit the test mode
or turn the power off and on once. If the same error occurs again, the main
PCB is faulty.

Check the operation of the main shaft brake and the stop position of the
main shaft (100 degrees).

The

is pressed while no sewing data has been transferred to the em-

broidery machine. Clear this error by the

STOP

. To start sewing, transfer

necessary data from the machine controller and press the

.

This is not usually displayed.

Press the

STOP

or turn on the F/B switch on the head to either side to cancel

the error and press the

. If the same error occurs again, there is a

possibility that the spindle is overloaded.

This is not usually displayed.

Turn the power off and on once. If the same error occurs again, the main
PCB is faulty.

Secure the bed. If the bed is secured, the bed sensor position may be
faulty. Readjust it.

Turn the power off and on once. If the same error occurs again, the main
PCB is faulty.

Turn the power off and on once. If the same error occurs again, the power
PCB is faulty.

Turn off the power and check the fan harness. Turn on the power again. If
the same error occurs again, the fan or the power PCB is faulty.

(1) The voltage setting is improper. -> Set it again.

(2) Press the

STOP

or turn on the F/B switch on the head to either side. If

the same error occurs again, the power PCB or the power supply is
faulty.

Turn the power off and on once.

Turn off the power and check the fan harness. Turn on the power again. If
the same error occurs again, the fan or the power PCB is faulty.

Turn the power off and on once. If the same error occurs again, the main
PCB is faulty.

This is not usually displayed.