beautypg.com

Scheduling a system reset, Viewing the system log – Asante Technologies 8000 User Manual

Page 81

background image

Viewing the System Log

Page 3-47

Scheduling a System Reset

You can schedule the IntraCore 8000 to automatically perform a reset from
one second up to 24 hours (86,400 seconds) in advance.

To schedule a reset, use the following procedure.

1

Open the System Reset Menu by typing r in the Configu-
ration Menu.

2

Type s to schedule a reset time (within the specified
range).

3

Enter the number of seconds the IntraCore 8000 will wait
before it automatically resets.

I Important: The maximum number of seconds that can

be entered is 86,400 (24 hours).

4

Press Return.

The IntraCore 8000 will reset automatically after the number of seconds you
specified.

Viewing the System Log

The IntraCore 8000 system log records and displays any major system
events on the switch, such as fatal errors, plugging in or removing a module,
etc.

To view the system log, use the following procedure.

1

Type l in the Configuration Menu. The System Log Menu
appears, as shown in Figure 3-26.