Image File Downloading Configuration

Page 3-43

Current Settings
Table 3-11 describes the settings shown in the X/Y/Z Modem Image File
Downloading Menu.

Table 3-11 X/Y/Z Modem Image File Downloading settings

Performing a Software Upgrade
Use the following procedure to upgrade the IntraCore 8000 software through
its serial (console) port.

1

In the Image File Download Configuration Menu, type x
to open the X/Y/Z Modem Image File Downloading
Menu.

2

Type x, y, or z to select the corresponding modem proto-
col.
K Note: For information about these protocols, see the

manual for your communications software.

3

Type c to select the console baud rate. The Baud Rate Set-
ting Menu appears, as shown in Figure 3-24. The maxi-
mum baud rate currently supported is 57,600 bps.

Setting

Description

Bank 1 Image Version/
Date

The version number and compilation date of runtime code that
is stored in memory Bank 1 on the IntraCore 8000.

Bank 2 Image Version/
Date

The version number and compilation date of runtime code that
is stored in memory Bank 2 on the IntraCore 8000.The (Run-
ning) designation indicates that the runtime code is currently
running on this Bank.

Download Protocol

Current setting of the IntraCore 8000’s serial download proto-
col.

Current Baud Rate

Transmission rate for the IntraCore 8000’s serial port.

Destination Bank

Number of the memory bank where the image file will down-
load.