Winland Electronics EA800-ip User Manual
Page 14

14
D-011-0152
System Configuration Parameters
Buzzer
• Enable
• Disable
Enabled
Enables and disables the buzzer when an alarm limit has
been exceeded or a warning condition exists.
WARNING
!
Selecting Disable for this parameter turns the audible
alarm buzzer off completely. No audible alarm tone
will sound when an alarm occurs if DISABLE is
selected.
RF Channel
11 (2405 MHz)
12 (2410 MHz)
13 (2415 MHz)
14 (2420 MHz)
15 (2425 MHz)
16 (2430 MHz)
17 (2435 MHz)
18 (2440 MHz)
19 (2445 MHz)
20 (2450 MHz)
21 (2455 MHz)
22 (2460 MHz)
23 (2465 MHz)
24 (2470 MHz)
25 (2475 MHz)
26 (2480 MHz)
channel 16
Selects the ISM band radio frequency (RF) channel for
transmission between the wireless sensors and EA800
console.
Table 4
System Configuration Parameters — continued