beautypg.com

Setting the time zone, Figure 3-23, Clock time zone – Accton Technology ES5508 User Manual

Page 73

background image

Basic Configuration

3-33

3

CLI – This example configures the switch to operate as an SNTP client and then
displays the current time and settings.

Setting the Time Zone

SNTP uses Coordinated Universal Time (or UTC, formerly Greenwich Mean Time,
or GMT) based on the time at the Earth’s prime meridian, zero degrees longitude. To
display a time corresponding to your local time, you must indicate the number of
hours and minutes your time zone is east (before) or west (after) of UTC.

Command Attributes
• Current Time – Displays the current time.
• Name – Assigns a name to the time zone. (Range: 1-29 characters)
• Hours (0-13) – The number of hours before/after UTC.
• Minutes (0-59) – The number of minutes before/after UTC.
• Direction – Configures the time zone to be before (east) or after (west) UTC.

Web – Select SNTP, Clock Time Zone. Set the offset for your time zone relative to
the UTC, and click Apply.

Figure 3-23 Clock Time Zone

CLI - This example shows how to set the time zone for the system clock.

Console(config)#sntp client

4-52

Console(config)#sntp poll 16

4-53

Console(config)#sntp server 10.1.0.19 137.82.140.80 128.250.36.2

4-52

Console(config)#exit
Console#show sntp

4-54

Current time:

Jan

6 14:56:05 2004

Poll interval: 60
Current

mode:

unicast

SNTP status : Enabled
SNTP server 10.1.0.19 137.82.140.80 128.250.36.2
Current server: 128.250.36.2
Console#

Console(config)#clock timezone Dhaka hours 6 minute 0 after-UTC

4-54

Console#