Show logging sendmail, Time commands, Table 4-22 – Accton Technology ES5508 User Manual
Page 263
![background image](/manuals/46339/263/background.png)
System Management Commands
4-51
4
Example
show logging sendmail
This command displays the settings for the SMTP event handler.
Command Mode
Normal Exec, Privileged Exec
Example
Time Commands
The system clock can be dynamically set by polling a set of specified time servers
(NTP or SNTP). Maintaining an accurate time on the switch enables the system log
to record meaningful dates and times for event entries. If the clock is not set, the
switch will only record the time from the factory default set at the last bootup.
Console(config)#logging sendmail
Console(config)#
Console#show logging sendmail
SMTP servers
-----------------------------------------------
192.168.1.19
SMTP minimum severity level: 7
SMTP destination email addresses
-----------------------------------------------
[email protected]
SMTP source email address: [email protected]
SMTP status: Enabled
Console#
Table 4-22 Time Commands
Command
Function
Mode
Page
sntp client
Accepts time from specified time servers
GC
sntp server
Specifies one or more time servers
GC
sntp poll
Sets the interval at which the client polls for time
GC
show sntp
Shows current SNTP configuration settings
NE, PE
clock timezone
Sets the time zone for the switch’s internal clock
GC
calendar set
Sets the system date and time
PE
show calendar
Displays the current date and time setting
NE, PE