beautypg.com

Show logging sendmail, Time commands, Table 4-22 – Accton Technology ES5508 User Manual

Page 263

background image

System Management Commands

4-51

4

Example

show logging sendmail

This command displays the settings for the SMTP event handler.

Command Mode

Normal Exec, Privileged Exec

Example

Time Commands

The system clock can be dynamically set by polling a set of specified time servers
(NTP or SNTP). Maintaining an accurate time on the switch enables the system log
to record meaningful dates and times for event entries. If the clock is not set, the
switch will only record the time from the factory default set at the last bootup.

Console(config)#logging sendmail
Console(config)#

Console#show logging sendmail
SMTP servers
-----------------------------------------------
192.168.1.19

SMTP minimum severity level: 7

SMTP destination email addresses
-----------------------------------------------
[email protected]

SMTP source email address: [email protected]

SMTP status: Enabled
Console#

Table 4-22 Time Commands

Command

Function

Mode

Page

sntp client

Accepts time from specified time servers

GC

4-52

sntp server

Specifies one or more time servers

GC

4-52

sntp poll

Sets the interval at which the client polls for time

GC

4-53

show sntp

Shows current SNTP configuration settings

NE, PE

4-54

clock timezone

Sets the time zone for the switch’s internal clock

GC

4-54

calendar set

Sets the system date and time

PE

4-55

show calendar

Displays the current date and time setting

NE, PE

4-55