Show system – Accton Technology ES5508 User Manual
Page 272

Command Line Interface
4-60
4
show system
This command displays system information.
Default Setting
None
Command Mode
Normal Exec, Privileged Exec
Command Usage
• For a description of the items shown by this command, refer to “Displaying
System Information” on page 3-9.
• The POST results should all display “PASS.” If any POST test indicates
“FAIL,” contact your distributor for assistance.
Example
Console#show system
System description: 24/48 L3 GE Switch
System OID string: 1.3.6.1.4.1.259.6.10.65
System information
System Up time: 0 days, 1 hours, 23 minutes, and 44.61 seconds
System Name
: [NONE]
System Location
: [NONE]
System Contact
: [NONE]
MAC address (unit1)
: 00-30-F1-D4-73-A0
Web server
: enable
Web server port
: 80
Web secure server
: enable
Web secure server port : 443
Telnet server
: enable
Telnet port
: 23
Authentication login
: local RADIUS none
Jumbo Frame
: Disabled
POST result
UART LOOP BACK Test..........PASS
DRAM Test....................PASS
Timer Test...................PASS
PCI Device 1 Test............PASS
I2C Bus Initialization ....... PASS
Switch Int Loopback Test ..... PASS
Crossbar Int Loopback Test ... PASS
Console#