28 lau_status_buzzer (0x0306), Lau_status_buzzer (0x0306) – Beijer Electronics SCOM RBC EN User Manual
Page 62
![background image](/manuals/459991/62/background.png)
Command Reference
62
Beijer Electronics, MAEN993
5.6.28 LAU_STATUS_BUZZER (0x0306)
Current Buzzer State
Returns the current buzzer state. The buzzer state can be changed using the SCOM
command “LAU_CONTROL_BUZZER”.
Supported since Firmware Version
LAUER RBC: 0.0.0.1
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
9
Example
Check whether the buzzer of the device at address 0.7 (group 0, address 7) is activat-
ed:
According to the data returned by the device at address 0.7 (group 0, address 7), the
buzzer is currently deactivated:
0
1
2
3
4
5
6
7...8
9
0x07
ADR
0x4C
0x41
0x55
0x02
ICHKH 0x03
0x06
ICHKD
0
1
2
3
4
5
6
7
8
0x06
ADR
0x4C
0x41
0x55
0x01
ICHKH
Ret
ICHKD
Ret
Value:
0x00: Buzzer enabled
0x01: Buzzer disabled
Type:
Byte
Length:
1
Description: Current buzzer state
0
1
2
3
4
5
6
7...8
9
0x07
0x07
0x4C
0x41
0x55
0x02
0x0D
0x03
0x06
0xF6
0
1
2
3
4
5
6
7
8
0x06
0x07
0x4C
0x41
0x55
0x01
0x0F
0x00
0xFF