Command Reference
54
Beijer Electronics, MAEN993
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
9
Example
Set the keypress mode of the device at address 0.3 (group 0, address 3) to the default
brightness value:
According to the data returned by the device at address 0.3 (group 0, address 3), the
keypress mode is set to the default brightness value:
0
1
2
3
4
5
6
7
8
0x06
ADR
0x4C
0x41
0x55
0x01
ICHKH
Ret
ICHKD
Ret
Value:
0x00: Brightness is set to darkest possible value (off)
0x01: Brightness is set to the value of the last received SCOM
BRT command
0x02: Brightness is set to default brightness value
0x03: Brightness is set to brightest possible value
0x04: Brightness does not change
Type:
Byte
Length:
1
Description: Indicates current keypress mode
0
1
2
3
4
5
6
7...9
10
0x07
0x03
0x4C
0x41
0x55
0x03
0x10
0x01
0xAA
0x02
0x52
0
1
2
3
4
5
6
7
8
0x06
0xE7
0x4C
0x41
0x55
0x01
0x13
0x02