22 lau_config_setkeypressmode (0x01aa), Lau_config_setkeypressmode (0x01aa) – Beijer Electronics SCOM RBC EN User Manual
Page 53

Command Reference
Beijer Electronics, MAEN993
53
5.6.22LAU_CONFIG_SETKEYPRESSMODE
(0x01AA)
Keypress Mode
The brightness of the Beijer Electronics RBCs can be configured adopt a determined
value if both dimmer keys are pressed for longer than one second. There are five key-
press modes:
• Backlight turns to darkest possible value (off )
• Backlight turns to the level of the last received SCOM BRT command
• Backlight turns to the default brightness, which can be configured as well
• Backlight turns to brightest possible value
• Backlight does not change
Supported since Firmware Version
LAUER RBC: 0.0.0.2
Command Stream
Note:
The changes made by this command will become active only after a restart of the de-
vice.
0
1
2
3
4
5
6
7...9
10
0x07
ADR
0x4C
0x41
0x55
0x03
ICHKH 0x01 0xAA
Param ICHKD
Param
Value:
0x00: Set brightness to darkest possible value (off)
0x01: Set brightness to the value of the last received SCOM
BRT command
0x02: Set brightness to default brightness value
0x03: Set brightness to brightest possible value
0x04: Do not change brightness
Type:
Byte
Length:
1
Description: Set the keypress mode