Command Reference

Beijer Electronics, MAEN993

17

5.3 VER

Unit ID and Model / Version Number

Requests the preassigned unit ID and model code, and the version of the serial
communications interface software. For compatibility reasons, this code is always
static and does not return information specific to Beijer Electronics RBC. To get de-
vice informations specific to Beijer Electronics RBC, such as firmware version etc.,
use the Lauer Extension command “LAU”.

Supported since Firmware Version
LAUER RBC: 0.0.0.1

Command Stream

(This command has no data)

Response Message (Acknowledge)

Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.

Maximum Lr for this Command
11

Example
Query the unit ID, model and version number of the device at address 0.7 (group 0,
address 7):

The device at address 0.7 (group 0, address 7) has returned “0x01 0x01 0x00”, which
indicates model 1, version 1.0:

0

1

2

3

4

5

6

0x07

ADR

0x56

0x45

0x52

0x00

ICHKH

0

1

2

3

4

5

6

7...9

10

0x06

ADR

0x56

0x45

0x52

0x03

ICHKH Unit ID / Version

ICHKD

Unit ID / Version

Value:

0255 each byte

Type:

Byte array

Length:

3

Description: Static unit ID, model and version number

0

1

2

3

4

5

6

0x07

0x07

0x56

0x45

0x52

0x00

0x04

0

1

2

3

4

5

6

7...9

10

0x06

0x07

0x56

0x45

0x52

0x03

0x02

0x01

0x01

0x00

0xFD