5 typ, Unit type and model number – Beijer Electronics SCOM RBC EN User Manual
Page 20
![background image](/manuals/459991/20/background.png)
Command Reference
20
Beijer Electronics, MAEN993
5.5 TYP
Unit Type and Model Number
Queries the device type and model.
Supported since Firmware Version
LAUER RBC: 0.0.0.1
Command Stream
(This command has no data)
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
(No data is returned, in case of a negative acknowledge)
Maximum Lr for this Command
23
Example
Query the unit type and model of the device at address 0.7 (group 0, address 7):
According to the data returned by the device (“Lauer RBC”) at address 0.7 (group 0,
address 7), this is a device of the Beijer Electronics RBC series:
0
1
2
3
4
5
6
0x07
ADR
0x54
0x59
0x50
0x01
ICHKH
0
1
2
3
4
5
6
7...7+[LEN]-1 7+[LEN]
0x06
ADR
0x54
0x59
0x50
LEN
ICHKH Type/Model
ICHKD
Type/Model
Value:
ASCII characters
Type:
String
Length:
1...15
Description: Device type and model
0
1
2
3
4
5
6
0x15
ADR
0x54
0x59
0x50
0x00
ICHKH
0
1
2
3
4
5
6
0x07
0x07
0x54
0x59
0x50
0x00
0xF4
0
1
2
3
4
5
6
7-15
0x06
0x07
0x54
0x59
0x50
0x09
0xEC
0x4C
0x61
0x75
0x65
7-15
16
0x72
0x20
0x52
0x42
0x43
0xB9