25 lau_status_displayadr (0x0302), Lau_status_displayadr (0x0302) – Beijer Electronics SCOM RBC EN User Manual
Page 58
![background image](/manuals/459991/58/background.png)
Command Reference
58
Beijer Electronics, MAEN993
5.6.25 LAU_STATUS_DISPLAYADR (0x0302)
Current Device Address
Returns the current device address. If the DIL (DIP) switch settings are used, this is
the address configured via DIL switches. The group bits within the address field are
always set to 0. If the DIL switch settings are overridden, this is the configured device
address.
Supported since Firmware Version
LAUER RBC: 0.0.0.1
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
9
Example
Read the current device address (including group) from the device at address 14.2
(group 14, address 2):
As expected, according to the data returned by the device at address 14.2 (group 14,
address 2), the devices current address is 14.2:
0
1
2
3
4
5
6
7...8
9
0x07
ADR
0x4C
0x41
0x55
0x02
ICHKH 0x03
0x02
ICHKD
0
1
2
3
4
5
6
7
8
0x06
ADR
0x4C
0x41
0x55
0x01
ICHKH
Ret
ICHKD
Ret
Value:
0...239 (0x00...0xEF)
Type:
Byte
Length:
1
Description: Current combined device group and address
0
1
2
3
4
5
6
7...8
9
0x07
0xE2
0x4C
0x41
0x55
0x02
0x32
0x03
0x02
0xFA
0
1
2
3
4
5
6
7
8
0x06
0xE2
0x4C
0x41
0x55
0x01
0x34
0xE2
0x1D