24 lau_control_reset (0x0207), Lau_control_reset (0x0207) – Beijer Electronics SCOM RBC EN User Manual
Page 57

Command Reference
Beijer Electronics, MAEN993
57
5.6.24LAU_CONTROL_RESET (0x0207)
Software Reset
This commands resets the software. All software initialization is done. This is not a
hardware reset or a power off/on. The parameter is for protection only. There must
be exactly this two bytes, or else it will answer with a negative acknowledge. This
command never returns a (positive) acknowledge; instead the reset is called.
Supported since Firmware Version
LAUER RBC: 0.0.0.1
Command Stream
Response Message (Acknowledge)
This command never returns a (positive) acknowledge.
Response Message (Negative Acknowledge)
Under normal operation conditions, a negative acknowledge message does not con-
tain any status data in response to this command. This response message is only sent,
if there is insufficient data in the command stream.
Maximum Lr for this Command
10
Example
Reset the device at address 1.8 (group 1, address 8):
The device at address 1.8 (group 1, address 8) could not be reset:
0
1
2
3
4
5
6
7...10
11
0x07
ADR
0x4C
0x41
0x55
0x03
ICHKH 0x02
0x07
Param ICHKD
Param
Value:
0xC6A5: This parameter is for protection purposes
Type:
Unsigned short
Length:
2
Description: Resets the software
0
1
2
3
4
5
6
7...8
9
0x15
ADR
0x4C
0x41
0x55
0x02
ICHKH
0x02
0x07
ICHKD
0
1
2
3
4
5
6
7...10
11
0x07
0x18
0x4C 0x41
0x55
0x04
0xFA
0x02 0x07 0xA5 0xC6 0x8B
0
1
2
3
4
5
6
7...8
9
0x15
0x18
0x4C
0x41
0x55
0x02
0xEE
0x02
0x07
0xF6