5.6.13 LAU_CONFIG_GETKEYPRESSMODE
(0x012A)
Keypress Mode
The brightness of the Beijer Electronics RBCs can be configured adopt a determined
value if both dimmer keys are pressed for longer than one second. There are five key-
press modes:
• Backlight turns to darkest possible value (off )
• Backlight turns to the level of the last received SCOM BRT command
• Backlight turns to the default brightness, which can be configured as well
• Backlight turns to brightest possible value
• Backlight does not change
Supported since Firmware Version
LAUER RBC: 0.0.0.2
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
9
0
1
2
3
4
5
6
7...8
9
0x07
ADR
0x4C
0x41
0x55
0x02
ICHKH 0x01
0x2A
ICHKD
0
1
2
3
4
5
6
7
8
0x06
ADR
0x4C
0x41
0x55
0x01
ICHKH
Ret
ICHKD
Ret
Value:
0x00: Brightness is set to darkest possible value (off)
0x01: Brightness is set to the value of the last received SCOM
BRT command
0x02: Brightness is set to default brightness value
0x03: Brightness is set to brightest possible value
0x04: Brightness does not change
Type:
Byte
Length:
1
Description: Indicates current keypress mode