beautypg.com

13 lau_config_getkeypressmode (0x012a), Lau_config_getkeypressmode (0x012a) – Beijer Electronics SCOM RBC EN User Manual

Page 36

background image

Command Reference

36

Beijer Electronics, MAEN993

5.6.13 LAU_CONFIG_GETKEYPRESSMODE

(0x012A)

Keypress Mode

The brightness of the Beijer Electronics RBCs can be configured adopt a determined
value if both dimmer keys are pressed for longer than one second. There are five key-
press modes:

• Backlight turns to darkest possible value (off )

• Backlight turns to the level of the last received SCOM BRT command

• Backlight turns to the default brightness, which can be configured as well

• Backlight turns to brightest possible value

• Backlight does not change

Supported since Firmware Version
LAUER RBC: 0.0.0.2

Command Stream

Response Message (Acknowledge)

Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.

Maximum Lr for this Command
9

0

1

2

3

4

5

6

7...8

9

0x07

ADR

0x4C

0x41

0x55

0x02

ICHKH 0x01

0x2A

ICHKD

0

1

2

3

4

5

6

7

8

0x06

ADR

0x4C

0x41

0x55

0x01

ICHKH

Ret

ICHKD

Ret

Value:

0x00: Brightness is set to darkest possible value (off)
0x01: Brightness is set to the value of the last received SCOM
BRT command
0x02: Brightness is set to default brightness value
0x03: Brightness is set to brightest possible value
0x04: Brightness does not change

Type:

Byte

Length:

1

Description: Indicates current keypress mode