beautypg.com

Extending your hand-held controller, 1 obtain new cable, Xtending your – Pulsafeeder MPC User Manual

Page 43: Ontroller, Obtain new cable

background image

12. Extending your Hand-Held Controller

The hand-held controller for your MPC can be placed as far as 1000 feet from
the pump with optional cable. It is recommended that all calibrations be
completed before the cable is lengthened, as these tasks are easier when the
pump and hand-held controller are close to each other.

To replace the cable for the hand-held unit:

POWER TO THE UNIT MUST BE OFF! A GROUNDING WRIST STRAP
SHOULD BE WORN WHEN MAKING CONNECTIONS TO ANY PCB

12.1 Obtain New Cable:

The following standard length cables are available from Pulsafeeder for use with
the MPC:


Cable Length

Part Number

Notes

6 feet

NP530130-000

Standard, supplied with all MPC controllers

Others per foot

NP530147-000 (1
ft)

NOTE: do not exceed 1,000 feet total length

12.2 Removal and Connection of the Cable from the

Handheld:

1. Open the handheld unit by removing the 4 screws on the face of the unit.

2. Open the unit by separating the cover from the base.

3. Disconnect the keypad from the Remote PCB by gently removing the

connector at the end of the keypad’s tail from the header on the PCB.

4. Make a note of what color lead is in each position of the terminal block

“J5”. Cut the tie-wrap that secures the cable. Loosen each of the 6
positions on the terminal block “J5” and remove each lead.

5. Loosen the outer domed nut on the liquid tight, releasing the tension on

the cable. Pull the cable through the liquid tight. Thread the new cable
through the liquid tight with enough length to reconnect to the terminal
block.

6. Cut the shield wire as close as possible to the outer insulation at the

remote end only.