beautypg.com

Installation, Owner’s responsibilities – Blodgett CNVX-14E User Manual

Page 7

background image

3

Installation

ELECTRICaL RaTINGS - GaS OVENS

BCX-14G/aa, BX-14G/aa aNd CNVX-14G/aa

TYPE OF GaS

GaS INPUT

VOLTaGE

PHaSE

aMPS

MOTOR

BCX-14G/aa
Natural

Steam - 50,000 BTU/Hr
Hot Air - 65,000 BTU/Hr
Total - 115,000 BTU/Hr

115

208-240

1
1

12

6

3/4 HP 208-240VAC, 3 phase,

50/60 Hz

Propane

Steam - 48,000 BTU/Hr
Hot Air - 65,000 BTU/Hr
Total - 113,000 BTU/Hr

115

208-240

1
1

12

6

3/4 HP 208-240VAC, 3 phase,

50/60 Hz

BX-14G/aa and CNVX-14G/aa
Natural

Hot Air - 65,000 BTU/Hr

115

208-240

1
1

12

6

3/4 HP 208-240VAC, 3 phase,

50/60 Hz

Propane

Hot Air - 65,000 BTU/Hr

115

208-240

1
1

12

6

3/4 HP 208-240VAC, 3 phase,

50/60 Hz

3/4” NPT connector for all U.S. and Canadian installations

RaTINGS - ELECTRIC aPPLIaNCES

BCX-14E/aa, BX-14E/aa aNd CNVX-14E/aa

VOLTaGE

Hz

KW

PHaSE

MaX LOad (aMPS

MOTOR

L1

L2

L2

208

60

19

3

53

53

50

3/4 HP 208-240VAC, 50/60 Hz

240

60

19

3

46

46

43

3/4 HP 208-240VAC, 50/60 Hz

480

60

19

3

23

23

21

3/4 HP 208-240VAC, 50/60 Hz

Owner’s Responsibilities

This manual is related to the following products: