3
Installation
ELECTRICaL RaTINGS - GaS OVENS
BCX-14G/aa, BX-14G/aa aNd CNVX-14G/aa
TYPE OF GaS
GaS INPUT
VOLTaGE
PHaSE
aMPS
MOTOR
BCX-14G/aa
Natural
Steam - 50,000 BTU/Hr
Hot Air - 65,000 BTU/Hr
Total - 115,000 BTU/Hr
115
208-240
1
1
12
6
3/4 HP 208-240VAC, 3 phase,
50/60 Hz
Propane
Steam - 48,000 BTU/Hr
Hot Air - 65,000 BTU/Hr
Total - 113,000 BTU/Hr
115
208-240
1
1
12
6
3/4 HP 208-240VAC, 3 phase,
50/60 Hz
BX-14G/aa and CNVX-14G/aa
Natural
Hot Air - 65,000 BTU/Hr
115
208-240
1
1
12
6
3/4 HP 208-240VAC, 3 phase,
50/60 Hz
Propane
Hot Air - 65,000 BTU/Hr
115
208-240
1
1
12
6
3/4 HP 208-240VAC, 3 phase,
50/60 Hz
3/4” NPT connector for all U.S. and Canadian installations
RaTINGS - ELECTRIC aPPLIaNCES
BCX-14E/aa, BX-14E/aa aNd CNVX-14E/aa
VOLTaGE
Hz
KW
PHaSE
MaX LOad (aMPS
MOTOR
L1
L2
L2
208
60
19
3
53
53
50
3/4 HP 208-240VAC, 50/60 Hz
240
60
19
3
46
46
43
3/4 HP 208-240VAC, 50/60 Hz
480
60
19
3
23
23
21
3/4 HP 208-240VAC, 50/60 Hz
Owner’s Responsibilities