9
Installation
deliming System Connection and Priming (BCX-14 units only)
dELIMING SYSTEM CONNECTION
1. Push deliming tube onto barbed fitting on oven back.
Figure 5
2. Cut deliming tube to length using the bottom of the
deliming fluid reservoir in its mounted position as a
guide. Install the jug weight on the deliming fluid res-
ervoir end of the deliming tube.
Figure 6
3. Insert the end of the deliming tube with the jug weight
into the deliming solution reservoir.
Figure 7
NOTE: If needed use supplied hose retainers and self
drilling screws to route the deliming tube away
from hot exhaust ports.
PRIME THE dELIMING PUMP
To prime the delime pump, use the following procedure for
your oven control.
Standard Control
1. Rotate the mode switch to COOL DOWN.
2. Press and hold both the Timer knob and the Steam on
Demand knob simultaneously. This will turn the pump
on.
3. Watch for deliming solution to flow through the tube.
Release the two knobs once the delime solution has
reached the barbed fitting on the back of the oven.
4. Once the pump is primed, you may turn the mode
switch to any position.
MenuSelect™ Control
1. Press the Maintenance key.
2. Scroll to select MANAGER PROGRAM. Push the
knob.
NOTE: If the manager password is engaged, it will
need to be entered to proceed.
3. Scroll to PRIME DELIME PUMP and push the knob.
4. The display reads, PUSH KNOB TO PRIME. Hold the
knob to activate the pump.
5. Watch for deliming solution to flow through the tube.
Release the knob once the delime solution has
reached the barbed fitting on the back of the oven.
6. Once primed, press the ESC key three times to exit.