9

Installation

deliming System Connection and Priming (BCX-14 units only)

dELIMING SYSTEM CONNECTION
1. Push deliming tube onto barbed fitting on oven back.

Figure 5

2. Cut deliming tube to length using the bottom of the

deliming fluid reservoir in its mounted position as a

guide. Install the jug weight on the deliming fluid res-

ervoir end of the deliming tube.

Figure 6

3. Insert the end of the deliming tube with the jug weight

into the deliming solution reservoir.

Figure 7

NOTE: If needed use supplied hose retainers and self

drilling screws to route the deliming tube away

from hot exhaust ports.

PRIME THE dELIMING PUMP
To prime the delime pump, use the following procedure for

your oven control.
Standard Control
1. Rotate the mode switch to COOL DOWN.
2. Press and hold both the Timer knob and the Steam on

Demand knob simultaneously. This will turn the pump

on.

3. Watch for deliming solution to flow through the tube.

Release the two knobs once the delime solution has

reached the barbed fitting on the back of the oven.

4. Once the pump is primed, you may turn the mode

switch to any position.

MenuSelect™ Control
1. Press the Maintenance key.
2. Scroll to select MANAGER PROGRAM. Push the

knob.

NOTE: If the manager password is engaged, it will

need to be entered to proceed.

3. Scroll to PRIME DELIME PUMP and push the knob.
4. The display reads, PUSH KNOB TO PRIME. Hold the

knob to activate the pump.

5. Watch for deliming solution to flow through the tube.

Release the knob once the delime solution has

reached the barbed fitting on the back of the oven.

6. Once primed, press the ESC key three times to exit.