Operation, Menuselect™ control for models bcx-14 and bx-14 – Blodgett CNVX-14E User Manual
Page 30
26
Operation
delime Fill Time - Set the length of time the boiler
continues to fill with deliming solution beyond the
standard water level in order to ensure all of the scale
present in the boiler is removed.
delime Interval - Set the length of time between de-
liming intervals
delime Time - Set the time during the day when the
display alerts the user to delime
Flush Interval - Set the length of time between boiler
flushes
Flush Time - Set the time during the day when the
display alerts the user to flush the boiler
4. After editing a function, press the center of the dial
to save.
5. When all desired functions have been edited, turn the
dial to highlight EXIT. Press the center of the dial to
exit the manager programming mode.
MenuSelect™ Control for Models BCX-14 and BX-14