10

Installation

Plumbing Connections

WaTER CONNECTION
NOTE: Hot water maximizes steam production but is not

required. Cold water may be supplied to both

inlets if hot water is not available.

Connect the appliance to quality water via a pressure

hose with 3/4” GHT (19mm) couplings. See below for

connections. A shut off valve is to be provided adjacent

to the oven.

WaRNING!!

Operating the appliance without the water reg-

ulator installed will invalidate your warranty.

This product must be installed by a licensed Plumber or

Gas Fitter when installed within the Commonwealth of

Massachusetts.

dRaIN CONNECTION
The drain should be run to an open floor drain avoiding

flexible hose that could sag and allow trapped water to

accumulate. The customer must supply the piping from

the oven to the drain.
Specific water/drain connection for City of Los Ange-

les
1. Each drain line from the appliance shall be routed

without dips or sags to terminate above the flood level

rim of an approved indirect waste receptor.

2. The appliance shall be installed in accordance with

the manufacturer’s printed instructions and the LAPC

and LAMC, 1999 editions.

3. A backflow protection device may be required by lo-

cal codes. If so, install on the potable water system

directly ahead of the appliance. The backflow protec-

tion device shall be any of the following: an approved

pressure type vacuum breaker installed at least 12”

above the highest point of use, a double check valve

backflow preventer or a reduced pressure principal

backflow preventer.

Figure 8

BCX-14G and BX-14G

CNVX-14G

BCX-14E and BX-14E

CNVX-14E

Gas connection

Electrical connection

Filtered/boiler

connection
Unfiltered/condensate

and spray hose

connection