beautypg.com

Installation, Owner’s responsibilities – Blodgett CNVX-14E User Manual

Page 6

background image

2

Installation

PLUMBING SPECIFICaTIONS

BCX-14G/aa, BCX-14E/aa

BX-14G/aa, and BX-14E/aa

CNVX-14G/aa

CNVX-14E/aa

WaTER
Water pressure

40 PSI minimum

50 PSI maximum

Water connection

3/4” garden hose - Hot and Cold water

3/4” garden hose for spray hose - Cold

water only

Water pressure regulator setting

Preset to 30 PSI (207 kPa)

Minimum requirements

TDS: 40-125 ppm
Hardness: 35-100 ppm
Chlorides: <25 ppm
Silica: <13 ppm
Chlorine: 0 ppm
pH: 7.0-8.5

dRaINaGE
Drain type

Atmospheric Vented Drain

Drain connection

2.00” (50.8mm) Copper

Maximum water drain temperature 140ºF (60ºC)

Owner’s Responsibilities

INSTaLLaTION RESPONSIBILITIES PRIOR TO SERVICE STaRTUP INSPECTION
You are entitled to a free start-up inspection service by

our factory ASAP. Before a factory representative arrives

to perform a startup procedure, the owner must already

have satisfied the following requirements.
1. Oven(s) are uncrated, stacked (if applies) and put in

place.

NOTE: Please refer to Leg Attachment and Stacking.
Maximum shelf loading - 60 lbs (27.3 Kg)