8

Installation

Plumbing Connections

WATeR ConneCTion
Blodgett BCT/BLCT ovens have two water connections.

Both are located at the back of the unit.
BCT/BLCT-61, 62, 101, 102 and 202 models
• 1 connection for raw water for the condensation jet.
• 1 connection for steam generation and the Combi

Wash jet in the oven chamber. Must meet the re-

quirements applying to water supplied to household

appliances.

Quench

Steam

Figure 3

BLCT-23, 6 and 10 mini Combi models
• 1 water connection. Must meet the requirements ap-

plying to water supplied to household appliances.

Water

connection

Figure 4

WARninG!!

if the water temperature exceeds 70°F (21°C),

problems with regard to Combi optima cali-

bration and cooling of the oven may occur.
The water connection must be carried out by

an authorized plumber in accordance with

existing local codes.
Clogged up water filters and dirt in the sole-

noid valves are not covered by the warranty.

To facilitate cleaning and servicing, the oven should be

connected with an approved flexible 3/4” hose. Perma-

nent installations should be fitted with a stop-tap and a

non-return valve.
Before connecting the oven to water, flush the tubes

thoroughly. Connect the oven.

DRAin ConneCTion
Blodgett ovens are equipped with a drain system that re-

moves surplus water from the oven chamber. This may

be condensed water from the products, or it may occur

when the oven chamber is cooled down with cold water,

or when the oven chamber is cleaned.

WARninG!!

Connection must be carried out by an autho-

rised plumber, to an open or closed drain.

The drain must never end directly beneath the

oven.

The drain must be of stainless steel or an equally tem-

perature-resistant material, have a diameter of at least 2”

(49 mm) and a fall of at least 3° or 5%.

This manual is related to the following products: