Appendix E. Status Table

The AVW200 status table contains system operating status information

accessible via DevConfig, terminal emulator, or another PakBus device such as

a datalogger. Status Table information is easily viewed by going to DevConfig |

AVW200| Connect | Data Monitor | Status. The status table can be viewed via a

terminal emulator and command 4.

The status information can be retrieved by the datalogger by using the CRBasic

GetVariable instruction. Following is an example of retrieving the BattVoltage

status of the AVW200 using the CRBasic GetVariables instruction:

Public RC,AVW_BV

GetVariables(RC,ComSDC7,200,200,0000,0,"Status","BattVoltage",AVW_BV,1)

DevConfig polls the status table at regular intervals, updating

status information.

TABLE E-1 is a comprehensive list of status table variables with brief

descriptions.

TABLE E-1. Status Fields and Descriptions

Status

Fieldname

Description

User can change?

Record No

Record number for this set of data

No

Time Stamp

Time the record was generated

No

OSversion

Version of the Operating System

No

OSdate

Date OS was released

No

ProgName

Name of the running program

No

ProgSig

Signature of the running program

No

StationName

User defined Station Name

Yes

Compileresults

Compile results of the running program

Yes

PakBusAddress

AV200 PakBus address

Yes

RfInstalled

Specifies the model number of the MaxStream radio

if it is recognized by the datalogger. It will have a

value of zero if there is no radio recognized by the

AVW200.

No

RfNetAddr

Specifies the radio network address of the built in

radio. This setting should be set to match the

network address for the RF401 base used to

communicate with the datalogger.

Yes

RfNetHopSeq

Specifies the hopping sequence that will be used for

the built-in radio. This value should be set to match

the value of the same setting for the RF401 base

station used to communicate with this datalogger.

Yes

NOTE