AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules

7.3 AVW200( ) Instruction Running in the Pipeline Mode

The following program is an example of how to run the AVW200 with a

CR1000 using multiple AVW200( ) instructions in the pipeline mode of

operation. When this CRBasic program first starts running, the information

specified in the AVW200( ) instruction is sent to the attached AVW200

interface module via the Com1 communication port and PakBus address 200.

Along with the instruction's parameter information, the CR1000 also sends its

clock information. Every 64 seconds, the CR1000 clock and measured data are

exchanged with the attached AVW200 interface module. The AVW200

interface module then determines how much time previous to the CR1000's

interval it should start making the vibrating wire measurement, so that it

completes the measurement series before the CR1000's execution interval.

In the example program below, a multiplexer is attached to each AVW200

channel. Using the multiplexers, sixteen sensors are measured on channel 1

and sixteen sensors are measured on channel 2. Both of the multiplexers will

share the same clock (CLK) and reset (RST) lines on the AVW200.

In this example program, a returned “Result” value (the first parameter in the

AVW200( ) instruction) of zero indicates successful communication and tells

us that the data values have been stored in the destination variable, in this case,

AVWDst(). If there is a failure in communication, the “Result” value

increments for each failure and the AVWDst() values are filled with NAN's.

The datalogger will retry communications three times before returning a failed

communication or incrementing the result (retries are every 3 seconds or

greater depending on the radio-power-cycle configuration). A negative value

returned for the “Result” variable indicates status information (e.g., a -3

indicates the AVW200 has not made the first measurement; -4 indicates that no

parameter information is available). Note that the “Result” variable in both

AVW200( ) instructions are the same. There is no reason to have different

“Result” variables for a given communication port in the pipeline mode.

In the Pipeline mode of operation the AVW200( ) instruction

cannot be in a conditional statement or in a subroutine. It is

recommended to place the instruction at the top of the program.

TABLE 7-3 shows wiring used for this example.

TABLE 7-3. Wiring for Example 7.3

Datalogger Port for

Cable Attachment

Cable Needed to

connect to AVW200

AVW200 Port or

Model

COM1 (control port

pairs C1/C2)

17855 Cable (pigtail to

DB9 male cable)

RS-232

NOTE

48