Appendix D. The Public Table

Values and Control Parameters for SDI-12 Communications

SDI12val(1) Frequency value obtained by SDI Recorder Instruction, if

used; unchanged if not using SDI-12.

SDI12val(2) Amplitude value obtained by SDI Recorder Instruction, if

used; unchanged if not using SDI-12.

SDI12val(3) Signal to noise ratio obtained by SDI Recorder Instruction,

if used; unchanged if not using SDI-12.

SDI12val(4) Signal to noise frequency obtained by SDI Recorder

Instruction, if used; unchanged if not using SDI-12.

SDI12val(5) Decay ratio obtained by SDI Recorder Instruction, if used;

unchanged if not using SDI-12.

SDI12val(6) Thermistor reading obtained by SDI Recorder Instruction, if

used; unchanged if not using SDI-12.

SDIChan

Channel used for SDI-12 measurement

SDIBFreq

Begin frequency used for SDI-12 measurement

SDIEFreq

End frequency used for SDI-12 measurement

SDIExVolt

Excitation voltage used for SDI-12 measurement

Value of Last Instruction That’s Running

Ch1Freq

Frequency value measured on channel 1

Ch1Amp

Amplitude value measured on channel 1

Ch1SNR

Signal to noise ratio measured on channel 1

Ch1SNRFreq Signal to noise frequency measured on channel 1
Ch1Decay

Decay ratio measured on channel 1

Ch1Therm

Thermistor reading measured on channel 1

Ch2Freq

Frequency value measured on channel 2

Ch2Amp

Amplitude value measured on channel 2

Ch2SNR

Signal to noise ratio measured on channel 2

Ch2SNRFreq Signal to noise frequency measured on channel 2
Ch2Decay

Decay ratio measured on channel 2

Ch2Therm

Thermistor reading measured on channel 2