AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules

Wireless communication requires the appropriate spread spectrum radio to be

connected to the datalogger (see TABLE 4-3). DevConfig is used to configure

the AVW206, AVW211, or AVW216 for RF communications (Section 5.1,

Connecting to DevConfig, and Section 5.2.1, Communications).

TABLE 4-3. Datalogger to Spread Spectrum Radio Connections

Vibrating Wire

Interface Model

Required Spread

Spectrum Radio

Model

Cable used for

datalogger to

radio connection

Radio Port for

Cable Attachment

Datalogger Port

for Cable

Attachment

AVW206

RF401

SC12

CS I/O

CS I/O

AVW211

RF411

SC12

CS I/O

CS I/O

AVW216

RF416

SC12

CS I/O

CS I/O

(1) The AVW206, AVW211, and AVW216 are not compatible

with the RF450, RF400, RF410, and RF415 spread spectrum

radios.

(2) For communication between the vibrating wire interface and

spread spectrum radio to be successful, the radio’s Protocol must

be set to PakBus Aware or PakBus Node.

Read more! Description of our antenna options is provided in Appendix

C. More information about using spread spectrum radios is provided in

the RF401/RF411/RF416 Spread Spectrum Data Radio/Modem manual.

4.5 Multiplexer Wiring

Wire the sensors to the multiplexer according to the multiplexer manual. Other

multiplexer wiring depends on whether the AVW200 will control the

multiplexer or the datalogger will control the multiplexer.

4.5.1 AVW200 Controlling the Multiplexer

For most applications, it is desirable to have the AVW200 control the

multiplexer. A CABLE4CBL or MUXSIGNAL cable connects to the

multiplexer’s COM terminals, and another CABLE4CBL cable or the

MUXPOWER cable connects to the multiplexer’s CLK and RESET terminals

(see FIGURE 4-4).

When two multiplexers are connected to the AVW200, they share

the CLK and RESET lines. Because of this, while one multiplexer

is making measurements, the other multiplexer will advance its

channels but without making any measurements.

NOTES