Connections, 1 sensor wiring (no multiplexers), Sensor wiring (no multiplexers) – Campbell Scientific AVW200-series Vibrating Wire Interfaces User Manual

Page 26

background image

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules

The following steps are used:

1. Access DevConfig to configure the AVW200 for SDI-12 communications.

Go to the Deployment/Measurement tab in DevConfig and enter the

SDI-12 Address, multiplexer type, begin frequency, end frequency, and

excitation (see Section 5.1, Connecting to DevConfig, and Section 5.2.2,

Measurement).

2. Use a CABLE4CBL-L cable to connect the AVW200 to the multiplexers

(see FIGURE 4-5).

SDI-12 uses the CLK and RESET on the multiplexer instead of

the CLK and RESET address on the AVW200.

3. Connect the sensors to the multiplexers.

Read more! Information about connecting the vibrating wire sensors to

the multiplexer is provided in the AM16/32B manual.

4. Use a CABLE4CBL-L cable to connect the multiplexers to the datalogger

(see FIGURE 4-6).

5. Use a CABLE3CBL-L cable to connect the C1 terminal on the AVW200

to a control port and ground on the datalogger.

6. Connect one end of the 19246 power cable to the 12V and G terminals on

the AVW200 and the other end to the 12V and G terminals on the

datalogger or external power supply.

Read more! You can find power and ground connection information in

Section 4.2, and datalogger connection information in Section 4.3.

7. Program the datalogger. Our CRBasic dataloggers use the SDI12Recorder

instruction and Edlog dataloggers (i.e., CR10X, CR23X) use Instruction

105. The SDI12Recorder instruction should only be run in the sequential

mode.

Read more! The SDI12Recorder instruction is discussed in Section 6.2.

An example CRBasic program is provided in Section 7.5, and an example

Edlog program is provided in Appendix G.

4. Connections

4.1 Sensor Wiring (no multiplexers)

Up to two vibrating wire sensors can be directly connected to the AVW200

(see FIGURE 4-1). Sensor cabling is sold as a part of the sensor (refer to the

sensor manual for wire colors). Cable options for connecting the AVW200 to

the datalogger are listed in TABLE 4-1.

NOTE