Table 7-4 Supported RMAP Command Codes
RMAP Command
Code
Description
Supported in SpaceWire
Router
“0000”
Not used
-
“0001”
Not used
-
“0010”
Read single address
Yes
“0011”
Read incrementing address
Yes
“0100”
Not used
-
“0101”
Not used
-
“0110”
Not used
-
“0111”
Read-modify-write incrementing address
Yes
“1000”
Write single address, no verify, no acknowledge No
“1001”
Write incrementing address, no verify, no
acknowledge.
No
“1010”
Write single address, no verify, send
acknowledge
No
“1011”
Write incrementing address, no verify, send
acknowledge.
No
“1100”
Write single address, verify data, no
acknowledge
No
“1101”
Write incrementing address, verify data, no
acknowledge.
No
“1110”
Write single address, verify data, send
acknowledge
Yes
“1111”
Write incrementing address, verify data, send
acknowledge.
No
7.6.2 Read Command
The read single address characteristics of the SpaceWire router are defined in Table 7-5.