beautypg.com

Spw-10x spacewire router, User manual, Preliminary – Atmel SpaceWire Router SpW-10X User Manual

Page 120: 4 error active register

background image

Ref.: UoD_SpW-10X_

UserManual

Issue: 3.4

SpW-10X

SpaceWire Router

User Manual

Date: 11

th

July 2008

Preliminary

120

WARNING

The default timeout intervals of 60-80 µs or 1.3 ms are short. It may be necessary to increase the
timeout interval by a configuration command writing to the router control register. When initially
prototyping a SpaceWire system it is advisable to set the timeout interval to 1.3 s and then decrease it
to an appropriate value once basic system operation has been established.

9.5.4 Error active Register

The error active register address is 259 (0x0000 0103).

The error active register indicates the Error Active bit of the each of the port control/status registers.
By reading from this register a network manager can determine which ports currently have errors. This
register is also used to clear the error bits of the port control/status registers. To do this a write
command is sent to the error active register with bits set for those errors that are to be cleared.

The error active register fields are shown in

Figure 9-6 and described in Table 9-11.

Error Active Configuration Port

0

30

1

31

Error Active SpaceWire and External Ports

Not used

Figure 9-6 Error Active Register Fields