Table 10-3 External port timing parameters

Description Symbol

Value

Units

Write enable setup time to CLK rising edge

T

EXTWRSU

5

ns,

min

Write enable hold time after CLK rising edge

T

EXTWRHLD

5

ns,

min

Write data setup time to CLK rising edge

T

EXTIDATSU

5

ns,

min

Write data hold time after CLK rising edge

T

EXTIDATHLD

5

ns,

min

CLK rising edge to full flag output

T

EXTFFCKO

5

ns,

min

CLK rising edge to full flag output

T

EXTFFCKO

18

ns,

max

Read enable setup time to CLK rising edge

T

EXTRDSU

5

ns,

min

Read enable hold time after CLK rising edge

T

EXTRDHLD

5

ns,

min

CLK rising edge to read data output

T

EXTODATCKO

5

ns,

min

CLK rising edge to read data output

T

EXTODATCKO

18

ns,

max

CLK rising edge to empty flag output

T

EXTEFCKO

5

ns,

min

CLK rising edge to empty flag output

T

EXTEFCKO

18

ns,

max

10.4 TIME-CODE INTERFACE TIMING PARAMETERS

The following diagrams define the timing parameters for the time-code input and output

EXT_TICK_IN

SEL_EXT_TIME

EXT_TIME_IN

T

TCLKIL

T

TCLKIH

T

TCLKISU

T

TCLKIHLD

Figure 10-4 Time-Code Input Interface