Appendix: Dickey-john Flow Meter Calibrations

Note: The flow sensor constant is stamped on the Dickey-john flow meter. Refer to the
Dickey-john manual for information on the density setting.

Flow meter calibration for Anhydrous Ammonia (NH

3)

Use the following formula for flow meter calibration for Dickey-john reading pounds of
anhydrous ammonia.

Flow sensor constant (pulses/in

3

) x 1728 (in

3

/ft

3

) x 5.11 (lbs. of anhydrous/gal.)

Density (lbs. of anhydrous/ft.

3

)

Flow meter calibration for nitrogen (N)

Use the following formula for flow meter calibration for Dickey-john reading pounds of
Nitrogen.

Flow sensor constant (pulses/in

3

) x 1728 (in

3

/ft

3

) x 4.22 (lbs. of Nitrogen/gal.)

Density (lbs. of Nitrogen/ft.

3

)