HP StorageWorks XP Remote Web Console Software User Manual
Page 146

Table 16 System parameter settings (TagmaStore AMS and TagmaStore WMS subsystems) (continued)
Parameter setting
Parameters
Pane name
You can either specify this parameter
or omit specifying this parameter.
RAM Microprogram Version
You can either specify this parameter
or omit specifying this parameter.
Option
System Parameter
Set this parameter to Reset of occurred.
Operation if the processor failure
occurs
You can either specify this parameter
or omit specifying this parameter.
WEB Title
Specify this parameter to ON for AMS
1000, AMS 500, AMS 200, and
WMS 100.
Specify this parameter to OFF for AMS
2500 and AMS 2300, and AMS
2100.
Write and verify mode
You can either specify this parameter
or omit specifying this parameter.
Port Option
Port Options
Set this parameter to Standard Mode.
Host Connection Mode 1
Host Connection Mode
Do not specify any parameters.
NOTE:
As for AMS 1000, AMS 500,
AMS 200, and WMS 100, do not
specify HISUP OFF mode either.
Host Connection Mode 2
NOTE:
You can either specify or omit any other parameters.
Relationship between serial numbers in device list on the LU operation panel and
TagmaStore AMS and TagmaStore WMS subsystem models
When the external array is a TagmaStore AMS or TagmaStore WMS subsystem, you can identify
the subsystem model from the serial number displayed in the Serial column in the Device list on the
LU Operation pane.
shows the relationship between serial numbers displayed in the Serial column
and subsystem models.
Table 17 Relation between serial numbers and subsystem models (TagmaStore AMS and TagmaStore
WMS subsystems)
Model
Displayed serial number
Storage subsystem
AMS 2500
87XXXXXX
AMS
AMS 2300
85XXXXXX
AMS 2100
83XXXXXX
WMS 100
71XXXXXX
WMS
NOTE:
In serial numbers, X is an arbitrary number or character.
Relation between the WWN of the port on the TagmaStore AMS or TagmaStore
WMS subsystem and controller
When the external array is a TagmaStore AMS or TagmaStore WMS subsystem, you can identify
the controller (controller 0 or controller 1) from the port's WWN.
146
Notes on connecting external arrays