Table 21 RAID Manager error codes for SSB1: B901, B9A8, B9A9, B9AD, B9AE (continued)

Cause of Error

RAID Manager
Command

SSB2

Since you specified Continuous Access Synchronous P-VOL as the Snapshot
S-VOL, the pair cannot be created.

paircreate

9747

Since you specified Continuous Access Synchronous S-VOL as the Snapshot
S-VOL, the pair cannot be created.

paircreate

9748

Since you specified Continuous Access Journal data volume or journal volume
in the intermediate site of 3DC cascading configuration as the Snapshot S-VOL,
the Snapshot pair cannot be created.

paircreate

9749

Since you specified Continuous Access Journal P-VOL as the Snapshot S-VOL,
the pair cannot be created.

paircreate

974a

Since you specified Continuous Access Journal S-VOL as the Snapshot S-VOL,
the pair cannot be created.

paircreate

974b

Since you specified Continuous Access Journal journal volume as the Snapshot
S-VOL, the pair cannot be created.

paircreate

974c

Since the volume you specified as the S-VOL has an S-VOL Disable attribute, the
command ends abnormally.

All commands

974f

Since you specified the volume with the VMA setting as the Snapshot S-VOL, the
pair cannot be created.

paircreate

9750

Since the Max LBA size of the volumes you specified as the Snapshot P-VOL and
S-VOL is different, the command ends abnormally.

paircreate, pairsplit,
pairresync, pairresync
-restore

9752

Since the number of slots of the volumes you specified as the Snapshot P-VOL
and S-VOL is different, the command ends abnormally.

paircreate, pairsplit,
pairresync, pairresync
-restore

9753

Since you specified the Thin Provisioning V-VOL as the Snapshot S-VOL, the pair
cannot be created.

paircreate

9754

Since you specified the Business Copy reserved volume as the Snapshot P-VOL,
the command ends abnormally.

All commands

9756

Since you specified the Auto LUN source volume as the Snapshot P-VOL, the
command ends abnormally.

All commands

9757

For information about using Auto LUN, contact HP Technical Support.

Since you specified the Auto LUN target volume as the Snapshot P-VOL, the
command ends abnormally.

All commands

9758

For information about using Auto LUN, contact HP Technical Support.

Since you specified the Auto LUN reserved volume as the Snapshot P-VOL, the
command ends abnormally.

All commands

9759

For information about using Auto LUN, contact HP Technical Support.

Since you specified the Business Copy P-VOL as the Snapshot S-VOL, the
command ends abnormally.

All commands

975a

Since you specified the Business Copy S-VOL as the Snapshot S-VOL, the
command ends abnormally.

All commands

975b

Since you specified the Business Copy reserved volume as the Snapshot S-VOL,
the command ends abnormally.

All commands

975c

Since you specified the Auto LUN source volume as the Snapshot S-VOL, the
command ends abnormally.

All commands

975d

For information about using Auto LUN, contact HP Technical Support.